monitoring and controlling plants and machinery at hydraulic systems

monitoring and controlling plants and machinery at hydraulic systems

fluid-Check ® For monitoring and controlling plants and machinery at hydraulic systems

What can I measure?
With the Flow rate sensor (QS) :

Monitoring flow rate and wear of pumps
Operability of accumulators
Filter transmittance
Heat exchangers
Nozzle flow rate
Speed of hydraulic motors

fluid check flowratesensor for monitorin and controlling

fluid check flowratesensor for monitorin and controlling

With the Leakage sensor (LS) :Monitoring flow rate and wear of pumps
Seal damages and leakage identification
fluid-Check Monitoring flow rate and wear of pumps

Description
Via a hole in the pipe (plastic deformation with the measuring connector serv-Clip® Type 2)- no cutting pipelines, the sensor is placed directly into the oil circuit. The measuring system is based on the calorimetric principle, measuring flow rate speed in Meter/Second. Inexpensive and rapid Mounting. tag cloud . Durable and compact design.
Installation from pipe 12 x 1,5 mm up to 5,5 mm wall thickness possible

For pipes over 3“ (88,9 mm) and wall thickness from 6 mm ask about our adapter SC-XE-607.

Calibration service :
You get pro sensor a data sheet with curves (comparison mA with l/min).

Inform us the ID of the pipeline and the wished measuring range from/to in l/min.
fluid-Check Monitoring flow rate and wear of pumps fluid-Check

Technical data
- Measuring range 0,05 …8 Meter/Second
- Flow rate QS up to 600 Liter/Minute
,depending on ID
- Leakage LS from 0,02 Liter/Minute,
- Pressure 630 bar ( 9100 psi)
- Temperat. range -20..80°C
- Threaded coupling G 3/8 male
- Accuracy +/- 2%
- Configuration 3 wires
- Output signal 4 … 20 mA (Analogue)
- Power supply 24 V DC +/- 10%; 150mA
- Connection M12 Universal system
- For pipes with Ø 12 mm and larger
- Display 6 LED lights
- Setting per Micro button
- Protection mode IP 65
- Sensor head stainless steel 1.4571
- Housing

PBT (QS-2-B-008 / LS-2-B…)

or stainless steel

(QS-1-B-008 / LS-1-B…)
(*) Special instructions and accessory for stainless steel pipes up to 5,5 mm wall thickness with SC-2 possible.